Milltronics PL-521 Instruction Manual

Browse online or download Instruction Manual for Unknown Milltronics PL-521. Milltronics PL-521 Instruction manual [en] User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - XPS/XCTTRANSDUCERS

33455210Rev. 1.8XPS/XCT SERIESTRANSDUCERSXPS/XCTTRANSDUCERSInstruction Manual PL-521 January 2001

Page 2 - Disclaimer of Liability

DO’S AND DON’TSInstallation shall only be performed by qualified personnel and in accordance with local governing regulations.Do not route cable openl

Page 3 - ABOUT THE TRANSDUCER

APPLICATIONS The transducer is to be used only in the manner outlined in this instruction manual.Normally, the transducer requires no cleaning or mai

Page 4 - SPECIFICATIONS

LIQUID APPLICATIONS - SUBMERGENCEIn applications where flooding is possible the transducer▼ can be fitted with a submergenceshield. The shield acts a

Page 5 - PL-521 5

LIQUID APPLICATIONS - STANDPIPESIn many applications access must be made via a standpipe. In such cases, Milltronics canprovide factory bonded flanged

Page 6 - MOUNTING

LIQUID APPLICATIONS - VOLUME1. Beam should not detect bin bottom. If this occurs use range extension parameters (on transceivers where available) to o

Page 7 - PL-521 7

LIQUID APPLICATIONS - WATER / WASTEWATERDIFFERENTIAL LEVELPUMP CONTROLSEWAGE LIFTPL-521 15

Page 8

SOLIDS APPLICATIONS - TYPICAL3. Transducer too close to material inlet. Falling material will intersect sound beam and cause erroneous rea

Page 9 - INTERCONNECTION

SOLIDS APPLICATIONS - SPECIALSTORAGE BIN WITH AGITATOR1. Transducer should be kept away from infeed.2. Where agitators are in use, use the Agitator Di

Page 10 - DO’S AND DON’TS

INSTALLATION DIAGRAM See Milltronics drawing number 0-9650017Z-DI-A for current drawing status.PL-521 18

Page 11 - APPLICATIONS

FOR CANADIAN HAZARDOUS INSTALLATIONS ONLYSee Milltronics drawing number 0-8850004Z-DI-A for current drawing status.PL-521 19

Page 12 - on applicable models

© Siemens Milltronics Process Instruments Inc. 2001Safety GuidelinesWarning notices must be observed to ensure personal safety as well as that of oth

Page 14 - LIQUID APPLICATIONS - VOLUME

ABOUT THE TRANSDUCERThe Echomax XPS / XCT series of transducers operates in association with Milltronics ultrasonic level monitoring products.The tran

Page 15 - PL-521 15

PL-521 4SPECIFICATIONSModel :XPS - 10 XPS - 15 XPS - 30 XPS - 40 XCT - 8 XCT - 12MeasurementRange,0.3 - 10 0.3 - 15 0.6 - 30 0.9 - 40 0.45 - 8 0.45 -

Page 16 - PL-521 16

OUTLINE AND DIMENSIONSradiating faceoptional submergence shieldrefer to associated instructionsoptional bonded flangerefer to associated instructionss

Page 17 - SOLIDS APPLICATIONS - SPECIAL

MOUNTINGDO’S AND DON’TSSpecial handling precautions must be taken to protect the face of the transducer from anydamage.Mount the transducer so that it

Page 18 - PL-521 18

MOUNTING - LIQUID APPLICATIONSFlexible ConduitBracketSubmersiblePlywoodrigid metal conduitcouplingtransducersafetychainflexibleconduitsteel channelcou

Page 19 - PL-521 19

MOUNTING - LIQUID APPLICATIONS (cont’d)nipple welded to blind flangecustomer flange, flat face onlyfactory flanged transducerboltgasketnutcouplingCust

Page 20

INTERCONNECTIONFor EnviroRangerERS 500 only,connect all threewires separately.When connecting to an EnviroRanger ERS 500, do NOT use coaxialcable, us

Comments to this Manuals

No comments